Medical Waste Incinerators for Covid19 Coronavirus Disease For United Nations WHO Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L…
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd….
KN95 Melt Blown Breathing mask machine
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected] Face Mask Machine for Coronavirus Disease COVID-19 Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono phase l Compressed Air…
Large General waste incinerator Burn Rate up to 250kg per hour
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank…
50-100-150-200 Kgs per Hour Solid Waste Incinerator on Sale
Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber….
Waste incinerator combustion chamber firebrick
waste incinerator combustion chamber firebrick WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm…
Incinerator Model TS100
Average loading capacity of 1,000 kg/day with maximum loading capacity of 1,200 kg. Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Website: www.hiclover.com Email: [email protected]: [email protected]
The incinerator with “PYROLYTIC” combustion
The incinerator control panel shall have all appropriate audible and visual alarms to ensure safe operation. This incinerator with “PYROLYTIC” combustion must have: 1.A combustion chamber of waste: oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load oA burner of lighting which the use is limited to the ignition of waste. oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory. oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.o Composition of the refractory; Refractory concrete :. Thickness : ≥100 mm. Nature: 42% of Al203Insulate in fibrous panels :Thickness: ≥75 mmNature: Calcium silicate.Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. Plate of combustion in Carborundum, avoiding the fixing of glass and slags A chamber of post combustion of gases oA burner of combustion of gases, oA device of injection of air allowing a total recombustion of gases, oA device of air inlet of cooling of waste gases, oA sheath of evacuation of the gases burnt. oCarcass in strong sheet steel with support of connection. oComposition of the refractory;Refractory concrete :Thickness : ≥150 mmNature: 65% of Al203Insulate in fibrous panel :Thickness: ≥85 mm Nature: CalciumoBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. oA secondary injection of air to ensure perfect oxygen content. A control box ensuring the complete cycle of combustion. Fan: oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including: A switch circuit breaker for each engine (ventilators and burners). A timer with adjustable temporization for the regulation of each burner. A regulator with digital watching for the temperature of combustion. A regulator with digital watching for the temperature of post combustion. Electric box The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C) Process Filtering system: Scruber to be mentionned as optionalEmission Standards Compliance: BS 3316 or équivalent standard Capacity to treat Plastic: Not less than 40% by weight
The incinerator with “PYROLYTIC” combustion
The incinerator control panel shall have all appropriate audible and visual alarms to ensure safe operation. This incinerator with “PYROLYTIC” combustion must have: 1.A combustion chamber of waste: oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load oA burner of lighting which the use is limited to the ignition of waste. oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory. oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.o Composition of the refractory; Refractory concrete :. Thickness : ≥100 mm. Nature: 42% of Al203Insulate in fibrous panels :Thickness: ≥75 mmNature: Calcium silicate.Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. Plate of combustion in Carborundum, avoiding the fixing of glass and slags A chamber of post combustion of gases oA burner of combustion of gases, oA device of injection of air allowing a total recombustion of gases, oA device of air inlet of cooling of waste gases, oA sheath of evacuation of the gases burnt. oCarcass in strong sheet steel with support of connection. oComposition of the refractory;Refractory concrete :Thickness : ≥150 mmNature: 65% of Al203Insulate in fibrous panel :Thickness: ≥85 mm Nature: CalciumoBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. oA secondary injection of air to ensure perfect oxygen content. A control box ensuring the complete cycle of combustion. Fan: oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including: A switch circuit breaker for each engine (ventilators and burners). A timer with adjustable temporization for the regulation of each burner. A regulator with digital watching for the temperature of combustion. A regulator with digital watching for the temperature of post combustion. Electric box The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C) Process Filtering system: Scruber to be mentionned as optionalEmission Standards Compliance: BS 3316 or équivalent standard Capacity to treat Plastic: Not less than 40% by weight
Containerized Mobile Incinerator
Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and…